新型固体进样汞镉测定仪测定固体样品中的镉

秦晓鹏 侯红 赵龙 孙在金 马瑾

秦晓鹏, 侯红, 赵龙, 孙在金, 马瑾. 新型固体进样汞镉测定仪测定固体样品中的镉[J]. 环境工程技术学报, 2017, 7(1): 114-119. doi: 10.3969/j.issn.1674-991X.2017.01.017
引用本文: 秦晓鹏, 侯红, 赵龙, 孙在金, 马瑾. 新型固体进样汞镉测定仪测定固体样品中的镉[J]. 环境工程技术学报, 2017, 7(1): 114-119. doi: 10.3969/j.issn.1674-991X.2017.01.017
QIN Xiaopeng, HOU Hong, ZHAO Long, SUN Zaijin, MA Jin. Determination of cadmium in solid samples using solid sampling atomic fluorescence spectrometry[J]. Journal of Environmental Engineering Technology, 2017, 7(1): 114-119. doi: 10.3969/j.issn.1674-991X.2017.01.017
Citation: QIN Xiaopeng, HOU Hong, ZHAO Long, SUN Zaijin, MA Jin. Determination of cadmium in solid samples using solid sampling atomic fluorescence spectrometry[J]. Journal of Environmental Engineering Technology, 2017, 7(1): 114-119. doi: 10.3969/j.issn.1674-991X.2017.01.017

新型固体进样汞镉测定仪测定固体样品中的镉

doi: 10.3969/j.issn.1674-991X.2017.01.017
详细信息
    作者简介:

    秦晓鹏(1986—),男,博士后,从事地下水及土壤污染修复研究, qinxp@craes.org.cn

    通讯作者:

    侯红 E-mail: houhong@craes.org.cn

  • 中图分类号: X502

Determination of cadmium in solid samples using solid sampling atomic fluorescence spectrometry

More Information
    Corresponding author: Hong HOU E-mail: houhong@craes.org.cn
  • 摘要: 使用由北京吉天仪器有限公司开发的新型固体进样汞镉测定仪(DCMA-200),对采集的土壤、大气颗粒物和固体废物样品中镉的浓度进行分析。在测试过程中,选择9种标准土(GBW07407、GBW07402、GBW07410、GBW07425、GBW07426、GBW07428、GBW07419、GBW07309和GBW07418),研究了进样量对测定的影响,并分别在1.0~10.0 mg称量范围内建立了标准曲线(R 2> 0.93)。当固体样品进样量为10.0 mg时,镉的检出限为0.004 7 mg/kg,测定下限为0.016 mg/kg。利用7种标准土(GBW07418和GBW07419除外)绘制的标准曲线,测得的5种实际土壤中镉的浓度与利用电感耦合等离子体质谱仪(ICP-MS)测得的结果较一致。但与ICP-MS测得的结果相比,利用该固体进样汞镉测定仪测得的大气颗粒物中镉的浓度明显偏高,而危险废物中镉的浓度偏低。因此,建议在检测某地区的固体样品时,尽可能选择该区域和该类固体样品的标准品来设计标准曲线,从而提高测试结果的准确性。

     

  • [1] DU P, LIU L, LI F . Distribution and fraction of Cd,Pb,Zn and Cu in the soil of an old smelting area in northeast China[J]. Environmental Geology, 2008,55:205-213.
    [2] NEZHAD M T K, MOHAMMADI K, GHOLAMI K , et al. Cadmium and mercury in topsoils of Babagorogor watershed,western Iran:distribution,relationship with soil characteristics and multivariate analysis of contamination sources[J]. Geoderma, 2014, 219/220:177-185.
    [3] WU J, BOYLE E A . Low blank preconcentration technique for the determination of lead,copper,and cadmium in small-volume seawater samples by isotope dilution ICP-MS[J]. Analytical Chemistry, 1997,69(13):2464-2470.
    doi: 10.1021/ac961204u pmid: 21639382
    [4] XU D, FAN W, LÜ H , et al. Simultaneous determination of traces amounts of cadmium,zinc,and cobalt based on UV-vis spectrometry combined with wavelength selection and partial least squares regression[J]. Spectrochimica Acta Part A:Molecular and Biomolecular Spectroscopy, 2014,123:430-435.
    doi: 10.1016/j.saa.2013.12.086 pmid: 24412797
    [5] SOSA V, BARCELÓ C, SERRANO N , et al. Antimony film screen-printed carbon electrode for stripping analysis of Cd(Ⅱ),Pb(Ⅱ),and Cu(Ⅱ) in natural samples[J]. Analytica Chimica Acta, 2015,855:34-40.
    doi: 10.1016/j.aca.2014.12.011 pmid: 25542087
    [6] CHEN J, TEO K C . Determination of cadmium,copper,lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction[J]. Analytica Chimica Acta, 2001,450:215-222.
    [7] JAHROMI E Z, BIDARI A, ASSADI Y , et al. Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry ultra trace determination of cadmium in water samples[J]. Analytica Chimica Acta, 2007,585:305-311.
    doi: 10.1016/j.aca.2007.01.007 pmid: 17386679
    [8] DUARTE A T, DESSUY M B, SILVA M M , et al. Determination of cadmium and lead in plastic material from waste electronic equipment using solid sampling graphite furnace atomic absorption spectrometry[J]. Microchemical Journal, 2010,96(1):102-107.
    [9] TÖRÖK P, $\dot{Z}$EMBERYOVÁ M . Comparison of chemical modifiers for direct determination of Cd,Cu and Zn in food stuffs by solid-sampling-ETAAS[J]. Food Chemistry, 2012,132(1):554-560.
    doi: 10.1016/j.foodchem.2011.10.068 pmid: 26434331
    [10] OLIVEIRA H R, MESKO M F, VALE M G , et al. Development of methods for the determination of cadmium and thallium in oil shale by-products with graphite furnace atomic absorption spectrometry using direct analysis[J]. Microchemical Journal, 2014,116:55-61.
    [11] 张晓红, 冯礼, 路东 , 等. 固体进样原子荧光用于测量农产品中的镉[J]. 现代科学仪器, 2012(6):157-161.

    ZHANG X H, FENG L, LU D , et al. Solid sampling atomic fluorescence spectrometry for cadmium determination in agricultural products[J]. Modern Scientific Instruments, 2012(6):157-161.
    [12] MAO X, LIU J, HUANG Y , et al. Assessment of homogeneity and minimum sample mass for cadmium analysis in powdered certified reference materials and real rice samples by solid sampling electrothermal vaporization atomic fluorescence spectrometry[J]. Journal of Agricultural and Food Chemistry, 2013,61(4):848-853.
    doi: 10.1021/jf3045473
    [13] 黄亚涛, 毛雪飞, 刘霁欣 , 等. 电热蒸发钨丝在线捕获原子荧光光谱法直接测定菠菜中痕量镉[J]. 分析化学, 2013,41(10):1587-1591.
    doi: 10.3724/SP.J.1096.2013.30300

    HUANG Y T, MAO X F, LIU J X , et al. Direct determination of ultratrace cadmium in ppinach by electrothermal vaporization atomic fluorescence spectrometry using on-line atom trap of tungsten coil[J]. Chinese Journal of Analytical Chemistry, 2013,41(10):1587-1591. doi: 10.3724/SP.J.1096.2013.30300
    [14] 国家环境保护总局. 生活饮用水标准检验方法金属指标:GB/T 5750.6—2006[S]. 北京: 中国标准出版社, 2006.
    [15] 卫生部,国家标准化管理委员会. 土壤环境监测技术规范:HJ/T 166—2004[S]. 北京: 中国环境科学出版社, 2004.
    [16] 环境保护部. 环境监测分析方法标准修订技术导则:HJ 168—2010[S]. 北京: 中国环境科学出版社, 2010.