CHEN Jian, ZHOU Xie, LI Ping, HUANG Wei, GONG Ling, DIAO Xiangwei. Application of sludge micro bulking technology in low-load domestic sewage treatment[J]. Journal of Environmental Engineering Technology, 2018, 8(2): 149-154. DOI: 10.3969/j.issn.1674-991X.2018.02.020
Citation: CHEN Jian, ZHOU Xie, LI Ping, HUANG Wei, GONG Ling, DIAO Xiangwei. Application of sludge micro bulking technology in low-load domestic sewage treatment[J]. Journal of Environmental Engineering Technology, 2018, 8(2): 149-154. DOI: 10.3969/j.issn.1674-991X.2018.02.020

Application of sludge micro bulking technology in low-load domestic sewage treatment

  • A town sewage treatment plant in Chongqing was studied, and it was found that the sewage treatment plant sludge index (SVI) was between 262-380 mL/g and at the sludge bulking state. Low dissolved oxygen and low sludge load were the main reasons of sludge bulking in the sewage treatment plant. Micro bulking of activated sludge in a certain extent could not only guarantee the stable discharge of CODCr, ammonia nitrogen, SS, TP and other indicators in the effluent, but also be conducive to the energy saving of the sewage treatment plant.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return