XU Su-shi, WANG Cheng-wen, WANG Di, DU Song. Study on UV-Fenton Treatment of Concentrated Water from Nanofiltration of Bio-treated Landfill Leachate[J]. Journal of Environmental Engineering Technology, 2013, 3(1): 65-70. DOI: 10.3969/j.issn.1674-991X.2013.01.012
Citation: XU Su-shi, WANG Cheng-wen, WANG Di, DU Song. Study on UV-Fenton Treatment of Concentrated Water from Nanofiltration of Bio-treated Landfill Leachate[J]. Journal of Environmental Engineering Technology, 2013, 3(1): 65-70. DOI: 10.3969/j.issn.1674-991X.2013.01.012

Study on UV-Fenton Treatment of Concentrated Water from Nanofiltration of Bio-treated Landfill Leachate

  • The treatment effect of concentrated water from nanofiltration of bio-treated landfill leachate was investigated through UV-Fenton process, and different factors on TOC removal such as H2O2 dosage, ferrous salt dosage, pH, temperature and reaction time were also studied. The results showed that UV-Fenton process could effectively remove the organic pollutant components. The H2O2 and FeSO4•7H2O dosage had a significant effect on TOC removal. The removal rate increased from 53.3% to 69.8% with H2O2 dosage increasing from 1 665 mg/L to 13 320 mg/L, and increased from 57.4% to 71.7% with FeSO4•7H2O dosage increasing from 367 mg/L to 5 500 mg/L. UV-Fenton system had a buffer effect on pH variation, and removal rate had a minor change with initial pH ranging from 2.0 to 6.0. With the temperature increasing from 20 to 60 ℃, TOC removal rate decreased slowly. TOC removal rate had a sharp increase in first 30 min and increased slowly later and, after 2 h, TOC removal rate no longer increased basically.