Volume 5 Issue 6
Nov.  2015
Turn off MathJax
Article Contents
ZHAO Li, ZHANG Dan, ZHOU Zhi-en, REN Li-hong, YIN Bao-hui, YUAN Rui. A Study on Emission Characteristics of Particulate Matters from Typical Industrial Combustion Sources in Chongqing City[J]. Journal of Environmental Engineering Technology, 2015, 5(6): 447-454. doi: 10.3969/j.issn.1674-991X.2015.06.071
Citation: ZHAO Li, ZHANG Dan, ZHOU Zhi-en, REN Li-hong, YIN Bao-hui, YUAN Rui. A Study on Emission Characteristics of Particulate Matters from Typical Industrial Combustion Sources in Chongqing City[J]. Journal of Environmental Engineering Technology, 2015, 5(6): 447-454. doi: 10.3969/j.issn.1674-991X.2015.06.071

A Study on Emission Characteristics of Particulate Matters from Typical Industrial Combustion Sources in Chongqing City

doi: 10.3969/j.issn.1674-991X.2015.06.071
More Information
  • Corresponding author: ZHANG Dan E-mail: zhang_dan_8888@126.com
  • Received Date: 2015-06-29
  • Rev Recd Date: 2015-08-17
  • Publish Date: 2015-11-20
  • The particle samples from the cement kilns and coal-fired boilers in Chongqing city were collected by using a flue-gas cascade dilution sampler. The samples were then classified into 12 levels by an electric low pressure impactor (ELPI), and the size distribution characteristic of particles (0.02~10 μm) from industrial sources analyzed. The results showed that the cement kiln exhibited double-peak type logarithmic distribution, with the peak respectively at the accumulation status (0.12 μm) and the near-coarse particle status (1.23-1.96 μm), while the particle number concentration of coal boilers source presented one single peak of accumulation status. The particle-number concentration and mass concentration of the large power plant were higher than other sources, with the peak value being 2.2×106 cm-3, and 174.2 mg/m3, respectively. The OC, Al, and Ca were relatively high in the cement kiln PM2.5, accounting for 17.96%, 17.32% and 9.90% of PM2.5, respectively, while Al, SO42-, and OC were relatively high in the coal-fired boiler PM2.5, accounting for 9.17%, 8.92% and 6.15%, respectively. Compared with carbonaceous and water-soluble fractions, the inorganic fraction contributed more to PM2.5 in the industrial sources, responsible for 44.28% in the cement kiln sources and 18.07% in the coal-fired boilers sources.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article Views(2065) PDF Downloads(1565) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return