Volume 3 Issue 3
May  2013
Turn off MathJax
Article Contents
YANG Peng-cheng, TIAN Zhi-yong, SONG Yong-hui, YANG Yong-zhe, FU Bo-siyuan, LI Kui. Comparative Experimental Study on A2O and MUCT Processes for the Improvement of Discharge Standards and Reconstruction of Wastewater Treatment Plant with SDAO Process[J]. Journal of Environmental Engineering Technology, 2013, 3(3): 195-201. doi: 10.3969/j.issn.1674-991X.2013.03.032
Citation: YANG Peng-cheng, TIAN Zhi-yong, SONG Yong-hui, YANG Yong-zhe, FU Bo-siyuan, LI Kui. Comparative Experimental Study on A2O and MUCT Processes for the Improvement of Discharge Standards and Reconstruction of Wastewater Treatment Plant with SDAO Process[J]. Journal of Environmental Engineering Technology, 2013, 3(3): 195-201. doi: 10.3969/j.issn.1674-991X.2013.03.032

Comparative Experimental Study on A2O and MUCT Processes for the Improvement of Discharge Standards and Reconstruction of Wastewater Treatment Plant with SDAO Process

doi: 10.3969/j.issn.1674-991X.2013.03.032
More Information
  • Corresponding author: SONG Yong-hui E-mail: songyh@craes.org.cn
  • Received Date: 2013-01-08
  • Rev Recd Date: 2013-01-30
  • Publish Date: 2013-05-20
  • Based on the biological nitrogen and phosphorous removal mechanisms, the treatment effects and differences of transforming SDAO process into A2O process and MUCT process without additional building and apparent structural modification were studied. The results showed that the removal efficiency of CODCr and NH4+-N in both processes could reach above 90.0%, but with the relatively low TN and TP removal efficiencies under the condition of influent C/N=3.25 during the early domestication period. Nitrogen and phosphorous removal efficiency could be considerably improved by supplementing additional carbon source. After improving the C/N to 6.75 and keeping the A2O process at stable operation, the TN and TP removal efficiencies of 75.6% and 78.8% could be reached with effluent TN of 15.6 mg/L and TP of 1.4 mg/L, respectively. The removal efficiency of MUCT process was not as good as A2O: the removal efficiencies of TN and TP were 62.8% and 37.3%, and the average effluent TN and TP were 25.3 and 2.8 mg/L, respectively. Step-feed could improve the removal efficiencies of MUCT: under stable operations, the TN and TP removal efficiencies could be improved to 72.8% and 86.8%, with effluent TN of 20.3 mg/L and TP of 0.9 mg/L, respectively. In conclusion, the A2O process had more obvious advantages than the MUCT process when used for the improvement of discharge standards and for the reconstruction of SDAO process. The effluent CODCr, NH4+-N and TN of A2O process met the requirements of Class 1A discharge standards of the National Standard (GB 18918-2002); while the effluent TP could meet the Class 1B standard, and additional chemical phosphorus removal was thus required to meet the Class 1A discharge standard.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article Views(2616) PDF Downloads(886) Cited by()