Volume 1 Issue 1
Jan.  2011
Turn off MathJax
Article Contents
SVANTE Wallin, HUANG Zhao-Kai, FAN Hai-Hua. Using Differential Optical Absorption Spectroscopy (DOAS) for Continuous Emission Monitoring and Process Gases[J]. Journal of Environmental Engineering Technology, 2011, 1(1): 38-45. doi: 10.3969/j.issn.1674-991X.2011.01.007
Citation: SVANTE Wallin, HUANG Zhao-Kai, FAN Hai-Hua. Using Differential Optical Absorption Spectroscopy (DOAS) for Continuous Emission Monitoring and Process Gases[J]. Journal of Environmental Engineering Technology, 2011, 1(1): 38-45. doi: 10.3969/j.issn.1674-991X.2011.01.007

Using Differential Optical Absorption Spectroscopy (DOAS) for Continuous Emission Monitoring and Process Gases

doi: 10.3969/j.issn.1674-991X.2011.01.007
  • Received Date: 2010-11-19
  • Rev Recd Date: 2010-12-11
  • Publish Date: 2011-01-20
  • The principle and system design of DOAS indicated the system could monitor multi-gas from UV wavelength to IR wavelength. After a series of test and identification from TüV, the DOAS system had proven to have a good performance on continuous emission monitoring in stationary pollution source and waste incineration, especially to monitor Hg, HCl, NH3 and HF. The DOAS system could monitor different concentrations of process gas with several paths using one analyzer and work well where was corrosive, high temperature and high level dust,which made it possible to monitor progress gases. The system also could monitor different concentrations of gases in different places. No extract sample system, faster response speed, multi-component and multi-path monitoring by one analyzer laid foundation for the DOAS a good competition on the market.

     

  • loading
  • [1]
    TARODO J.Continuous emission monitoring[M].World Cement,2003,34:67-72.
    [2]
    NOXON J F.Nirogen dioxide in the stratosphere and troposphere measurement by ground-based absorption spectroscopy[J].Science,1975,189:547-549.
    [3]
    PLATT U,PERNER D,PÄTZ H W.Simultaneous measurements of atmospheric CH2O, O3 and NO2 by differential optical absorption[J].Geophys Res,1979,84:6329.
    [4]
    PLATT U,PERNER D.Measurements of atmospheric trace gases by long path differential UV/visible absorption spectroscopy: optical and laser remote sensing(A83-47766 23-35)[R].Berlin:Springer-Verlag,1983:97-105.
    [5]
    王东东,朱彬,王静. 利用差分吸收光谱系统对O3, SO2和NO2的监测分析[J].环境科学研究,2009,22(6):650-655.
    [6]
    GRABER W K, AUBENBERGER R T. Atmospheric trace gas measurements by Differential Optical Absorption Spectroscopy(DOAS):intercomparison with conventional techniques(TM-52-89-01)[R].Swiss: Paul Scherrer Institute,1989.
    [7]
    SANDRONI S, CERUTTI C, NORIEGA A,et al. Air quality measurements in Brussels(1993-1994) [R].European Commission Report EUR 16091EN.
    [8]
    付强,谢品华,王瑞斌.大气环境质量监测系统与传统点式采样监测法可比性研究[J].中国环境监测,2003,19(2):27-28.
    [9]
    U S EPA. Ambient air monitoring reference and equivalent methods: equivalent method designations[J]. Federal Register,1995,60(2):21518.
    [10]
    Institute for Environmental Protection and Power Technology.Report on the suitability tests of the OPSIS AR 500 measuring system for ozone marketed by Opsis AB, Furulund, NO. 936/807014/B[R].Cologne,Germany:TÜV Rheinland,1999.
    [11]
    MCERTS, Sira Certification Service.Product conformity certificate-AR500 open path monitor:Sira MC 040048/00 [R].England:MCERTS,2004.
    [12]
    PLATT U,PERNER D.Detection of nitrous acid in the atmosphere by differential optical absorption[J].Geophys Res,1979,6:917.
    [13]
    EDNER H.,SUNESSON A,WALLIN S,et al. Differential optical absorption spectroscopy system used for atmospheric mercury monitoring.[J]Appl Opt,1986,25:403.
    [14]
    Institute for Environmental Protection and Power Technology.Report on the suitability test of the AR 602 Z multi-constituent measuringsystem for SO2, NO and NO2 marketed by OPSIS AB, Furulund / Sweden. No. 936/800009 [R].Cologne,Germany:TÜV Rheinland,1991.
    [15]
    Institute for Environmental Protection and Power Technology .Report on the exemplary performance test of the multi-component emission measuring system OPSIS AR602Z of OPSIS AB, Furulund/Sweden, for metallic mercury. No. 936/804002/Hg [R].Cologne, Germany:TÜV Rheinland,1994.
    [16]
    LINDQVIST O,SCHAGER P.Continuous measurements of mercury in flue gases from waste incinerators and combustion plants[R].VDI BERICHTE 838. 1990:401-421.
    [17]
    建设部人事教育司,建设部科学技术司,建设部科技发展促进中心.城市生活垃圾焚烧处理技术[M].北京:中国建筑工业出版社,2003:44.
    [18]
    Official Journal of the European Communities.Directive 2000/76/EC of the European Parliament and of the Council of 4 December 2000 on the incineration of waste[S]EU. L 332 28.12.2000:91,109.
    [19]
    国家环境保护总局. GB18485-2001  生活垃圾焚烧污染控制标准[S].北京:中国标准出版社,2001.
    [20]
    Institute for Environmental Protection and Power Technology.Report on the suitability test of the AR 602 Z multi-constituent measuringsystem for NH3 marketed by OPSIS AB, Furulund/Sweden. No. 936/800010[R].Cologne,Germany:TÜV Rheinland,1992.
    [21]
    Institut fur Umweltschutz und Energietechnik, Bericht uber die eignungsprufung der Mehrkomponenten-Emissionssmesseinrichtung OPSIS AR 602 Z der Firma OPSIS AB, Furulund Sweden , zur messungen des feuchtegehaltes. Nr. 936/800010/2[R].Deutchland:TÜV Köln,1993.
    [22]
    Institut fur Umweltschutz und Energietechnik,Bericht über die modellhafte Eignungsprüfung der Mehrkomponenten – Emissionsmesseinrichtung OPSIS AR 602 Z der Firma OPSIS AB, Furulund/Schweden,für Phenol und Formaldehyd. Nr. 936/802011[R].Deutschland:TÜV Köln,1994.
    [23]
    Institute for Environmental Protection and Power Technology.Supplementary tests: AR602Z for NH3, SO2 and NO2, AR650 for HCl, H2O and CO, OPSIS AB, Furulund/Sweden. No.936/807024/A[R].Cologne,Germany:TÜV,1999.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article Views(6073) PDF Downloads(2187) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return